Approx. Rs 3,500 / Piece

HS50-50 and HS55 are a lightning arresters type 1 according to EN 61643-11 and IEC 61643-1. These are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0 – 1 (according to IEC 1312-1 and EN 62305) for lightning current equipotential bonding in power supply systems entering the building.

The lightning arresters are constructed as an encapsulated multiple spark gaps for installation in main switchboards. They are is mainly intended for use in TNC systems. For TNS and TT systems it is necessary to combine these arresters with lightning arrester HS100 (or JK110) which is recommended for equipotential bonding between N and PE.

HS55 arrester is intended for special installations in industrial buildings requiring max. continuous operating voltage of 440 V AC. The main use of HS55 arrester is in main switchboards of large industrial buildings and places with high risk of a direct lightning strike.

Lightning Arresters

Lightning Arresters

Approx. Rs 3,200 / Unit

HS50-50 and HS55 are a lightning arresters type 1 according to EN 61643-11 and IEC 61643-1. These are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0 – 1 (according to IEC 1312-1 and EN 62305) for lightning current equipotential bonding in power supply systems entering the building.

The lightning arresters are constructed as an encapsulated multiple spark gaps for installation in main switchboards. They are is mainly intended for use in TNC systems. For TNS and TT systems it is necessary to combine these arresters with lightning arrester HS100 (or JK110) which is recommended for equipotential bonding between N and PE.

The main use of HS50-50 is in industrial installations such as transformers, the main switchboards of large industrial buildings and places with high risk of a direct lightning strike. It is also suitable for applications in unmeasured parts of electrical installation (before electrometer) according to VDN Directive, 2nd Edition 2004 (TAB 2000).

Lightning Arresters

Lightning Arresters

Approx. Rs 3,000 / Unit

HS100 is a total current spark gap type 1 according to EN 61643-11 and IEC 61643-1 and is intended for use in TNS and TT systems (3+1 or 1+1) at the boundaries of LPZ 0 – 1. HS100 is to be installed between N and PE only.

JK110 Lightning Arresters

JK110 Lightning Arresters

Approx. Rs 2,800 / Unit

HS50-50 and HS55 are a lightning arresters type 1 according to EN 61643-11 and IEC 61643-1. These are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0 – 1 (according to IEC 1312-1 and EN 62305) for lightning current equipotential bonding in power supply systems entering the building.

The lightning arresters are constructed as an encapsulated multiple spark gaps for installation in main switchboards. They are is mainly intended for use in TNC systems. For TNS and TT systems it is necessary to combine these arresters with lightning arrester HS100 (or JK110) which is recommended for equipotential bonding between N and PE.

JK110 is a total current spark gap type 1 according to EN 61643-11 and is intended for use in TNS and TT systems (3+1 or 1+1) at the boundaries of LPZ 0 – 1. JK110 is to be installed between N and PE only.

Lightning Arresters

Lightning Arresters

Approx. Rs 2,800 / Unit

HZ110 is a lightning arrester type 1 according to EN 61643-11 and IEC 61643-1. These are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0 – 1 (according to IEC 1312-1 and EN 62305) for lightning current equipotential bonding in power supply systems entering the building.

The lightning arrester is constructed as an encapsulated multiple spark gap for  installation in main switchboards. HZ110 is mainly intended for use in TNC systems.

High-power lightning arrester HZ110 is intended for use in areas with a high frequency of storm days. The main use of HZ110 arrester is in industrial installations such as transformers or the main switchboards of large industrial buildings.
X
Provide Us More Details
Is this Requirement:

One Time Regular

How soon do you want this:

Immediate After 1 month

Purpose of Requirement:

Reselling End Use Raw Material

X

Looking for Spark gap lightning arresters - TYPE 1 ?

    country-ico

    We will contact you soon !

    Anurag Gupta

    (Director)

    Hakel India

    Patparganj, New Delhi, Delhi, India

    More Categories

    View All Categories »
    Send SMS
    Contact Us