Hakel India New Delhi, Delhi

Send SMS
Contact Us

Arresters For Protection Of Signal Systems

DTB 1/6 /L Surge Protection Devices

DTB 1/6 /L Surge Protection Devices

Approx. Rs 2,500 / Unit

DTB-L, DTB-AR and DTB-ART is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nomnal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. DTB-AR and DTB-ART types are designed for the protection of equipment using DSL technology. Maximum discharge current of DTB-L is 20kA (8/20) and 2kA (8/20) for DTB-AR and DTB-ART types. For the protection of telephone lines it is recommended to use a type with nominal voltage UN=170V (with code mark “T”). The connection of protected lines is carried out by screw terminals for type DTB-L and by RJ45 connectors for types DTB-AR and DTB-ART.

DTB 1/12 /L Surge Protection Devices

DTB 1/12 /L Surge Protection Devices

Approx. Rs 2,500 / Unit

DTB-L, DTB-AR and DTB-ART is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nomnal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. DTB-AR and DTB-ART types are designed for the protection of equipment using DSL technology. Maximum discharge current of DTB-L is 20kA (8/20) and 2kA (8/20) for DTB-AR and DTB-ART types. For the protection of telephone lines it is recommended to use a type with nominal voltage UN=170V (with code mark “T”). The connection of protected lines is carried out by screw terminals for type DTB-L and by RJ45 connectors for types DTB-AR and DTB-ART.

DTB 1/48 /L Surge Protection Devices

DTB 1/48 /L Surge Protection Devices

Approx. Rs 2,500 / Unit

DTB-L, DTB-AR and DTB-ART is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nomnal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. DTB-AR and DTB-ART types are designed for the protection of equipment using DSL technology. Maximum discharge current of DTB-L is 20kA (8/20) and 2kA (8/20) for DTB-AR and DTB-ART types. For the protection of telephone lines it is recommended to use a type with nominal voltage UN=170V (with code mark “T”). The connection of protected lines is carried out by screw terminals for type DTB-L and by RJ45 connectors for types DTB-AR and DTB-ART.

DTB 1/T /L Surge Protection Devices

DTB 1/T /L Surge Protection Devices

Approx. Rs 2,500 / Unit

DTB-L, DTB-AR and DTB-ART is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nomnal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. DTB-AR and DTB-ART types are designed for the protection of equipment using DSL technology. Maximum discharge current of DTB-L is 20kA (8/20) and 2kA (8/20) for DTB-AR and DTB-ART types. For the protection of telephone lines it is recommended to use a type with nominal voltage UN=170V (with code mark “T”). The connection of protected lines is carried out by screw terminals for type DTB-L and by RJ45 connectors for types DTB-AR and DTB-ART.

DTB 1/6 Surge Protection Devices

DTB 1/6 Surge Protection Devices

Approx. Rs 2,500 / Unit

DTB, DTB-R is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20) for type DTB and 2kA (8/20) for DTB-R type. For the protection of telephone lines it is recommended to use DTB type with nominal voltage UN = 170V (with code mark “T”). The connection of protected lines is carried out by screw terminals for type DTB and by RJ45 connectors for type DTB-R.

DTB 1/12 Surge Protection Devices

DTB 1/12 Surge Protection Devices

Approx. Rs 2,500 / Unit

DTB, DTB-R is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20) for type DTB and 2kA (8/20) for DTB-R type. For the protection of telephone lines it is recommended to use DTB type with nominal voltage UN = 170V (with code mark “T”). The connection of protected lines is carried out by screw terminals for type DTB and by RJ45 connectors for type DTB-R.

DTB 1/24 Surge Protection Devices

DTB 1/24 Surge Protection Devices

Approx. Rs 2,500 / Unit

DTB, DTB-R is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20) for type DTB and 2kA (8/20) for DTB-R type. For the protection of telephone lines it is recommended to use DTB type with nominal voltage UN = 170V (with code mark “T”). The connection of protected lines is carried out by screw terminals for type DTB and by RJ45 connectors for type DTB-R.

DTB 1/48 Surge Protection Devices

DTB 1/48 Surge Protection Devices

Approx. Rs 2,500 / Unit

DTB, DTB-R is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20) for type DTB and 2kA (8/20) for DTB-R type. For the protection of telephone lines it is recommended to use DTB type with nominal voltage UN = 170V (with code mark “T”). The connection of protected lines is carried out by screw terminals for type DTB and by RJ45 connectors for type DTB-R.

DTB 1/T Surge Protection Devices

DTB 1/T Surge Protection Devices

Approx. Rs 2,500 / Unit

DTB, DTB-R is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20) for type DTB and 2kA (8/20) for DTB-R type. For the protection of telephone lines it is recommended to use DTB type with nominal voltage UN = 170V (with code mark “T”). The connection of protected lines is carried out by screw terminals for type DTB and by RJ45 connectors for type DTB-R.

DTB 1/6 /R Surge Protection Devices

DTB 1/6 /R Surge Protection Devices

Approx. Rs 2,500 / Unit

DTB, DTB-R is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20) for type DTB and 2kA (8/20) for DTB-R type. For the protection of telephone lines it is recommended to use DTB type with nominal voltage UN = 170V (with code mark “T”). The connection of protected lines is carried out by screw terminals for type DTB and by RJ45 connectors for type DTB-R.

DTB 1/12 /R Surge Protection Devices

DTB 1/12 /R Surge Protection Devices

Approx. Rs 2,500 / Unit

DTB, DTB-R is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20) for type DTB and 2kA (8/20) for DTB-R type. For the protection of telephone lines it is recommended to use DTB type with nominal voltage UN = 170V (with code mark “T”). The connection of protected lines is carried out by screw terminals for type DTB and by RJ45 connectors for type DTB-R.

DTB 1/24 /R Surge Protection Devices

DTB 1/24 /R Surge Protection Devices

Approx. Rs 2,500 / Unit

DTB, DTB-R is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20) for type DTB and 2kA (8/20) for DTB-R type. For the protection of telephone lines it is recommended to use DTB type with nominal voltage UN = 170V (with code mark “T”). The connection of protected lines is carried out by screw terminals for type DTB and by RJ45 connectors for type DTB-R.

DTB 1/48 /R Surge Protection Devices

DTB 1/48 /R Surge Protection Devices

Approx. Rs 2,500 / Unit

DTB, DTB-R is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20) for type DTB and 2kA (8/20) for DTB-R type. For the protection of telephone lines it is recommended to use DTB type with nominal voltage UN = 170V (with code mark “T”). The connection of protected lines is carried out by screw terminals for type DTB and by RJ45 connectors for type DTB-R.

DTB 1/T /R Surge Protection Devices

DTB 1/T /R Surge Protection Devices

Approx. Rs 2,500 / Unit

DTB, DTB-R is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20) for type DTB and 2kA (8/20) for DTB-R type. For the protection of telephone lines it is recommended to use DTB type with nominal voltage UN = 170V (with code mark “T”). The connection of protected lines is carried out by screw terminals for type DTB and by RJ45 connectors for type DTB-R.

DTB1/AR Surge Protection Devices

DTB1/AR Surge Protection Devices

Approx. Rs 2,500 / Unit

DTB-L, DTB-AR and DTB-ART is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nomnal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. DTB-AR and DTB-ART types are designed for the protection of equipment using DSL technology. Maximum discharge current of DTB-L is 20kA (8/20) and 2kA (8/20) for DTB-AR and DTB-ART types. For the protection of telephone lines it is recommended to use a type with nominal voltage UN=170V (with code mark “T”). The connection of protected lines is carried out by screw terminals for type DTB-L and by RJ45 connectors for types DTB-AR and DTB-ART.

DTB1/ART Surge Protection Devices

DTB1/ART Surge Protection Devices

Approx. Rs 2,500 / Unit

DTB-L, DTB-AR and DTB-ART is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nomnal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. DTB-AR and DTB-ART types are designed for the protection of equipment using DSL technology. Maximum discharge current of DTB-L is 20kA (8/20) and 2kA (8/20) for DTB-AR and DTB-ART types. For the protection of telephone lines it is recommended to use a type with nominal voltage UN=170V (with code mark “T”). The connection of protected lines is carried out by screw terminals for type DTB-L and by RJ45 connectors for types DTB-AR and DTB-ART.

DTE 1/6 Surge Protection Devices

DTE 1/6 Surge Protection Devices

Approx. Rs 2,500 / Unit

DTE is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20). For the protection of telephone lines it is recommended to use a type with nominal voltage UN=170V (with code mark “T”).

DTE 1/12 Surge Protection Devices

DTE 1/12 Surge Protection Devices

Approx. Rs 2,500 / Unit

DTE is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20). For the protection of telephone lines it is recommended to use a type with nominal voltage UN=170V (with code mark “T”).

DTE 1/24 Surge Protection Devices

DTE 1/24 Surge Protection Devices

Approx. Rs 2,500 / Unit

DTE is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20). For the protection of telephone lines it is recommended to use a type with nominal voltage UN=170V (with code mark “T”).

DTE 1/48 Surge Protection Devices

DTE 1/48 Surge Protection Devices

Approx. Rs 2,500 / Unit

DTE is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20). For the protection of telephone lines it is recommended to use a type with nominal voltage UN=170V (with code mark “T”).

DTE 1/T Surge Protection Devices

DTE 1/T Surge Protection Devices

Approx. Rs 2,500 / Unit

DTE is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20). For the protection of telephone lines it is recommended to use a type with nominal voltage UN=170V (with code mark “T”).

DTNVE 1/24/5 Surge Protection Devices

DTNVE 1/24/5 Surge Protection Devices

Approx. Rs 2,500 / Unit

DTNVE 5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 5A.

These devices consist of MOVs only. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 12V-230V. Maximum discharge current is different according to various types from 2kA (8/20) to 10kA (8/20).

DTNVE 1/24/0,5 Surge Protection Devices

DTNVE 1/24/0,5 Surge Protection Devices

Approx. Rs 2,550 / Unit

DTNVE 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-115V. Maximum discharge current is 10kA (8/20).

DTNVE 1/30/0,5 Surge Protection Devices

DTNVE 1/30/0,5 Surge Protection Devices

Approx. Rs 2,200 / Unit

DTNVE 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-115V. Maximum discharge current is 10kA (8/20).

DTNVE 1/48/0,5 Surge Protection Devices

DTNVE 1/48/0,5 Surge Protection Devices

Approx. Rs 2,450 / Unit

DTNVE 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-115V. Maximum discharge current is 10kA (8/20).

DTNVE 1/30/5 Surge Protection Devices

DTNVE 1/30/5 Surge Protection Devices

Approx. Rs 2,640 / Unit

DTNVE 5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 5A.

These devices consist of MOVs only. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 12V-230V. Maximum discharge current is different according to various types from 2kA (8/20) to 10kA (8/20).

DTNVE 1/12/5 Surge Protection Devices

DTNVE 1/12/5 Surge Protection Devices

Approx. Rs 2,250 / Unit

DTNVE 5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 5A.

These devices consist of MOVs only. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 12V-230V. Maximum discharge current is different according to various types from 2kA (8/20) to 10kA (8/20).

DTNVE 1/6/0,5 Surge Protection Devices

DTNVE 1/6/0,5 Surge Protection Devices

Approx. Rs 2,650 / Unit

DTNVE 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-115V. Maximum discharge current is 10kA (8/20).

DTNVE 1/48/0,5 /L Surge Protection Devices

DTNVE 1/48/0,5 /L Surge Protection Devices

Approx. Rs 3,000 / Unit

DTNVE 0,5-L is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN < 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-80V. Maximum discharge current is 20kA (8/20).

DTNVE 1/48/5 Surge Protection Devices

DTNVE 1/48/5 Surge Protection Devices

Approx. Rs 3,000 / Unit

DTNVE 5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 5A.

These devices consist of MOVs only. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 12V-230V. Maximum discharge current is different according to various types from 2kA (8/20) to 10kA (8/20).

DTNVE 1/12/0,5 Surge Protection Devices

DTNVE 1/12/0,5 Surge Protection Devices

Approx. Rs 2,500 / Unit

DTNVE 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-115V. Maximum discharge current is 10kA (8/20).

DTNVE 1/80/0,5 /L Surge Protection Devices

DTNVE 1/80/0,5 /L Surge Protection Devices

Approx. Rs 3,000 / Unit

DTNVE 0,5-L is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN < 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-80V. Maximum discharge current is 20kA (8/20).

DTNVE 1/6/0,5 /L Surge Protection Devices

DTNVE 1/6/0,5 /L Surge Protection Devices

Approx. Rs 3,000 / Unit

DTNVE 0,5-L is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-80V. Maximum discharge current is 20kA (8/20)

DTNVE 1/12/0,5 /L Surge Protection Devices

DTNVE 1/12/0,5 /L Surge Protection Devices

Approx. Rs 2,500 / Unit

DTNVE 0,5-L is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN < 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-80V. Maximum discharge current is 20kA (8/20).

DTNVE 1/115/0,5 Surge Protection Devices

DTNVE 1/115/0,5 Surge Protection Devices

Approx. Rs 2,500 / Unit

DTNVE 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-115V. Maximum discharge current is 10kA (8/20).

DTNVE 1/80/5 Surge Protection Devices

DTNVE 1/80/5 Surge Protection Devices

Approx. Rs 4,000 / Piece

DTNVE 5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 5A.

These devices consist of MOVs only. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 12V-230V. Maximum discharge current is different according to various types from 2kA (8/20) to 10kA (8/20).

DTNVE 1/110/0,5 Surge Protection Devices

DTNVE 1/110/0,5 Surge Protection Devices

Approx. Rs 2,500 / Unit

DTNVE 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-115V. Maximum discharge current is 10kA (8/20).

DTNVE 1/80/0,5 Surge Protection Devices

DTNVE 1/80/0,5 Surge Protection Devices

Approx. Rs 3,000 / `unit

DTNVE 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-115V. Maximum discharge current is 10kA (8/20).

DTE 1/6 /L Surge Protection Devices

DTE 1/6 /L Surge Protection Devices

Approx. Rs 3,000 / Unit

DTE-L is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use a type with nominal voltage UN=170V (with code mark “T”).

DTE 1/12 /L Surge Protection Devices

DTE 1/12 /L Surge Protection Devices

Approx. Rs 2,500 / Unit

DTE-L is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use a type with nominal voltage UN=170V (with code mark “T”).

DTE 1/24 /L Surge Protection Devices

DTE 1/24 /L Surge Protection Devices

Approx. Rs 2,000 / Unit

DTE-L is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use a type with nominal voltage UN=170V (with code mark “T”).

DTE 1/48 /L Surge Protection Devices

DTE 1/48 /L Surge Protection Devices

Approx. Rs 2,500 / Unit

DTE-L is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use a type with nominal voltage UN=170V (with code mark “T”).

DTE 1/T /L Surge Protection Devices

DTE 1/T /L Surge Protection Devices

Approx. Rs 2,300 / Unit

DTE-L is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use a type with nominal voltage UN=170V (with code mark “T”).

DTNVE 1/24/0,5 /L Surge Protection Devices

DTNVE 1/24/0,5 /L Surge Protection Devices

Approx. Rs 2,300 / Unit

DTNVE 0,5-L is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN < 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-80V. Maximum discharge current is 20kA (8/20).

DTNVE 1/30/0,5 /L Surge Protection Devices

DTNVE 1/30/0,5 /L Surge Protection Devices

Approx. Rs 2,300 / Unit

DTNVE 0,5-L is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN < 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-2). These devices are produced for nominal voltage within the range of 6V-80V. Maximum discharge current is 20kA (8/20).

DTB 485 /L Arresters

DTB 485 /L Arresters

Approx. Rs 2,500 / Unit

Type DTB 485 /L Number of protected pairs 1 Nominal voltage UN 6 V Max. continuous operating voltage UC 7,2 V AC
Nominal current IN 0,1 A D1 Total lightning current (10/350) Iimp 5 kA D1 Lightning current (10/350) line/PE Iimp 2,5 kA C2 Max. discharge current (8/20) Imax 20 kA Voltage protection level at In Up 15 V Voltage protection level at 1kV/μs UP 9 V Article number 41485

DTB 2/485 /L Arresters

DTB 2/485 /L Arresters

Approx. Rs 3,000 / Unit

Type DTB 2/485 /L Number of protected pairs 2 Nominal voltage UN 6 V AC
Max. continuous operating voltage UC 7,2 V AC
Nominal current IN 0,1 A D1 Total lightning current (10/350) Iimp 5 kA D1 Lightning current (10/350) line/PE Iimp 2,5 kA C2 Max. discharge current (8/20) Imax 20 kA Voltage protection level at In Up 15 V Voltage protection level at 1kV/μs UP 9 V Article number 41486

DTB 485 Arresters

DTB 485 Arresters

Approx. Rs 3,000 / Unit

Type DTB 485 Number of protected pairs 1 Nominal voltage UN 6 V AC
Max. continuous operating voltage UC 7,2 V AC
Nominal current IN 0,1 A D1 Total lightning current (10/350) Iimp 5 kA C2 Max. discharge current (8/20) Imax 10 kA Voltage protection level at In Up 15 V Voltage protection level at 1kV/μs UP 9 V

DTB 2/485 Arresters

DTB 2/485 Arresters

Approx. Rs 3,000 / Unit

It was a complex range of surge protection devices designed for protection of data, communication, measuring and control lines aganist surge effects.

DTB 485 /R Arresters

DTB 485 /R Arresters

Approx. Rs 3,000 / Unit

Type DTB 485 /R Number of protected pairs 1 Nominal voltage UN 6 V AC
Max. continuous operating voltage UC 7,2 V AC
Nominal current IN 0,1 A C2 Max. discharge current (8/20) Imax 2 kA Voltage protection level at In Up 15 V Voltage protection level at 1kV/μs UP 9 V Article number 41785
X
Provide Us More Details
Is this Requirement:

One Time Regular

How soon do you want this:

Immediate After 1 month

Purpose of Requirement:

Reselling End Use Raw Material

X

Looking for Arresters For Protection Of Signal Systems ?

country-ico

We will contact you soon !

Anurag Gupta

(Director)

Hakel India

Patparganj, New Delhi, Delhi, India

More Categories

View All Categories »
Send SMS
Contact Us