Hakel India New Delhi, Delhi

Send SMS
Contact Us

Arresters For Protection Of Signal Systems IV

Surge Protection Devices

Surge Protection Devices

Approx. Rs 6,700 / Unit

DT 3/T /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 6,800 / Unit

DT 4/12 /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,000 / Unit

DT 4/48 /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Arresters

Arresters

Approx. Rs 7,500 / Unit

DT 4/232 /L

Arresters

Arresters

Approx. Rs 7,200 / Unit

It was a complex range of surge protection devices designed for protection of data, communication, measuring and control lines aganist surge effects.

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,300 / Unit

DT 4/T /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,800 / Unit

DT 4/24 /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 8,200 / Unit

DT 4/6 /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 8,200 / Unit

DT 3/48 /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,800 / Unit

DTNV 2/12/0,5

DTNV 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-48V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 8,300 / Unit

DTNV 2/24/0,5

DTNV 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-48V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 8,000 / Unit

DTNV 2/48/0,5

DTNV 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-48V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 8,300 / Unit

DTNV 3/12/5

DTNV 5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 5A.

These devices consist of MOVs only. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 12V-110V. Maximum discharge current is different according to various types from 2kA (8/20) to 8kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 8,000 / Unit

DTNV 3/24/5

DTNV 5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 5A.

These devices consist of MOVs only. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 12V-110V. Maximum discharge current is different according to various types from 2kA (8/20) to 8kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,400 / Unit

DTNV 3/48/5

DTNV 5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 5A.

These devices consist of MOVs only. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 12V-110V. Maximum discharge current is different according to various types from 2kA (8/20) to 8kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,500 / Unit

DTNV 3/110/5

DTNV 5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 5A.

These devices consist of MOVs only. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 12V-110V. Maximum discharge current is different according to various types from 2kA (8/20) to 8kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,600 / Unit

DTNV 4/12/0,5

DTNV 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-48V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 8,000 / Unit

DTNV 4/6/0,5

DTNV 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-48V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,650 / Unit

DTNV 3/80/5

DTNV 5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 5A.

These devices consist of MOVs only. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 12V-110V. Maximum discharge current is different according to various types from 2kA (8/20) to 8kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 6,500 / Unit

DTNV 4/24/0,5

DTNV 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-48V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 6,800 / Unit

DTNV 4/48/0,5

DTNV 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-48V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20).
X
Provide Us More Details
Is this Requirement:

One Time Regular

How soon do you want this:

Immediate After 1 month

Purpose of Requirement:

Reselling End Use Raw Material

X

Looking for Arresters For Protection Of Signal Systems IV ?

    country-ico

    We will contact you soon !

    Anurag Gupta

    (Director)

    Hakel India

    Patparganj, New Delhi, Delhi, India

    More Categories

    View All Categories »
    Send SMS
    Contact Us