Arresters For Protection Of Signal Systems III

Arresters

Arresters

Approx. Rs 1,800 / Unit

It was a complex range of surge protection devices designed for protection of data, communication, measuring and control lines aganist surge effects.

Arresters

Arresters

Approx. Rs 3,200 / Unit

It was designed to protect data & communications line. All protected lines are equipped with transient voltage suppressor diode which eliminates common mode & differential mode.

Surge Protection Devices

Surge Protection Devices

Approx. Rs 3,350 / Unit

DTB 4/100M 5cat

These surge protection devices intended for computer networks are specially designed for securing a faultless data transfer within computer networks category 5. They protect input electronic circuits of network cards against damage caused by surge effects in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 and higher according to EN 62305. It is recommended to use these protection devices at the input of protected equipment.

Models:

DTB*/100M 5cat is suitable for mounting on a wall. DTB 2/100M5 cat protects two pairs and DTB 4/100M 5cat protects four pairs of conductors.

Hakelnet Arresters

Hakelnet Arresters

Approx. Rs 1,700 / Unit

Hakelnet 4/250M 6 cat is designed to protect data and communications lines acc. to EN 501 73-1 ed.3, class E. All protected lines are equipped with Transient Voltage Suppressor Diode which eliminates common mode and differential mode surge effects during computer networks operation.

Hakelnet 4/250M 6cat consists of a plastic box and patch cords which are terminated with RJ45 connectors. Required length of patch cords (a, b) is to be specified by customer.

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,000 / Unit

DT 1/24

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 6,400 / Unit

DT 1/T

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,200 / Unit

DT 2/12

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 6,700 / Unit

DT 2/48

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,600 / Unit

DT 3/T

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 6,500 / Unit

DT 4/6
DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 8,200 / Unit

DT 2/T

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 8,250 / Unit

DT 2/24

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,200 / Unit

DT 2/6

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,400 / Unit

DT 1/48

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,500 / Unit

DT 4/48

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,900 / Unit

DT 1/6 /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,350 / Unit

DT 1/24 /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,200 / Unit

DT 1/T /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Arresters

Arresters

Approx. Rs 7,500 / Unit

Surge Arrester for Protection of Equipments. Communication lines and power supply lines.

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,400 / Unit

DT 2/6 /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Arresters

Arresters

Approx. Rs 7,200 / Unit

It was a complex range of surge protection devices designed for protection of data, communication, measuring and control lines aganist surge effects.

Surge Protection Devices

Surge Protection Devices

Approx. Rs 6,870 / Unit

DT 1/48 /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 6,700 / Unit

DT 1/12 /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 8,300 / Unit

DT 4/T

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,650 / Unit

DT 2/12 /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN < 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,500 / Unit

DT 2/48 /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Arresters

Arresters

Approx. Rs 6,800 / Unit

It was a complex range of surge protection devices designed for protection of data, communication, measuring and control lines aganist surge effects.

Surge Protection Devices

Surge Protection Devices

Approx. Rs 6,500 / Unit

DT 3/6 /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,250 / Unit

DT 3/12 /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,400 / Unit

DT 2/232

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,350 / Unit

DT 2/24 /L

DT is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) -1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,1A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-170V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20). For the protection of telephone lines it is recommended to use DT type with nominal voltage UN=170V (with code mark “T”).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,600 / Unit

DTNV 1/6/0,5

DTNV 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-48V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,400 / Unit

DTNV 1/12/5

DTNV 5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 5A.

These devices consist of MOVs only. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 12V-110V. Maximum discharge current is different according to various types from 2kA (8/20) to 8kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,500 / Unit

DTNV 1/24/5

DTNV 5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 5A.

These devices consist of MOVs only. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 12V-110V. Maximum discharge current is different according to various types from 2kA (8/20) to 8kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 8,200 / Unit

DTNV 1/48/5

DTNV 5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 5A.

These devices consist of MOVs only. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 12V-110V. Maximum discharge current is different according to various types from 2kA (8/20) to 8kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,800 / Unit

DTNV 1/110/5

DTNV 5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 5A.

These devices consist of MOVs only. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 12V-110V. Maximum discharge current is different according to various types from 2kA (8/20) to 8kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,500 / Unit

DTNV 2/6/0,5

DTNV 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-48V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,300 / Unit

DTNV 1/80/5

DTNV 5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 5A.

These devices consist of MOVs only. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 12V-110V. Maximum discharge current is different according to various types from 2kA (8/20) to 8kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 6,700 / Unit

DTNV 1/48/0,5

DTNV 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-48V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20).

DTNV 1/24/0,5 Surge Protection Devices

DTNV 1/24/0,5 Surge Protection Devices

Approx. Rs 7,850 / Unit

DTNV 1/24/0,5

DTNV 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-48V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20).

Surge Protection Devices

Surge Protection Devices

Approx. Rs 7,800 / Unit

DTNV 1/12/0,5

DTNV 0,5 is a complex range of surge protection devices designed for protection of data, communication, measuring and control lines against surge effects. These surge protection devices are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0A(B) - 1 according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to IEC 61643-21. The nominal current of individual protected lines IN< 0,5A.

These devices consist of gas discharge tubes, series impedance and transils. The number of protected pairs is optional (1-4). These devices are produced for nominal voltage within the range of 6V-48V. Maximum discharge current is 10kA (8/20), in case of “L” design the maximum discharge current is 20kA (8/20).
X
Provide Us More Details
Is this Requirement:

One Time Regular

How soon do you want this:

Immediate After 1 month

Purpose of Requirement:

Reselling End Use Raw Material

X

Looking for Arresters For Protection Of Signal Systems III ?

    country-ico

    We will contact you soon !

    Anurag Gupta

    (Director)

    Hakel India

    Patparganj, New Delhi, Delhi, India

    More Categories

    View All Categories »
    Send SMS
    Contact Us